Description
24mm x 19mm perimeter wall angle should be fixed to the structure with appropriate fixings at a maximum of 600mm on centers
PRODUCT QUANTITIES REQUIRED FOR M2 CONSTRUCTION
Wall Angle 0.6 Im
download data sheet
Description
W Shadow Angle can be used for ceiling systems which provides a shadow line finish.
PRODUCT QUANTITIES REQUIRED FOR M2 CONSTRUCTION
Wall Angle 0.6 Im
download data sheet
Description
Knauf Fire Resistant Gypsum Boards have been evaluated to meet the requirement for Type X
(Special Fire - Resistant) compliant board as defined by ASTM C 1396.These boards are specifically
designed for use in areas where fire protection is required.
Field of Application
Knauf Type X Fire Resistant Gypsum Boards (GW-TX) are high performance gypsum boards used as the cladding component of drywall constructions such as:
Fire rated partitions using metal or wooden frame
Fire rated suspended ceilings using metal or wooden frames
Fire rated furring and wall linings
Fire rated shaftwalls
Encasement of steel beams or column with fire protection requirements
Description
Knauf Fire and Water Resistant Gypsum Boards have been evaluated to meet the requirement for Type X
(Special Fire-Resistant) compliant board as defined by ASTM C1396. These boards are specifically designed for use in areas where fire and moisture protection is required.
Field of Application
Knauf Type X Fire and Water Resistant Gypsum Boards (GB-WRTX) are high performance gypsum boards used as the cladding component of drywall constructions in humid areas such as:
Fire Rated Partition or Ceilings of Kitchens / Bathrooms
Description
Galvanized lightweight steel sections to be used as a perimeter channels for Knauf ceilings are cold-rolled from high-grade galvanized steel sheets that complies with EN 10327
Product Description
Galvanized lightweight steel sections to be used as perimeter channels for Knauf D11 Ceiling and W623 Wall Lining System. Knauf ceiling metal sections are cold-rolled from high-grade galvanized steel, which complies with EN 10327. All Knauf metal sections comply with EN 14195 and DIN 18182-1
Field of Application
Nonious Ceiling System / Wall Lining System
download data sheet
Description
Galvanized lightweight steel sections to be used as a perimeter channels for Knauf ceilings are cold-rolled from high-grade galvanized steel sheets that complies with ASTM 645 - 09a Standard.
Description
Galvanised lightweight steel sections to be used as perimeter channels for Knauf D11 Ceiling and W623 Wall Lining System. Knauf ceiling metal sections are cold-rolled from high-grade galvanized steel, which complies with EN 10327. All Knauf metal sections comply with EN 14195 and DIN 18182-1
Description
Accessory used as adjustable brackets for Knauf W623 Wall Lining System or as suspenders for Knauf D11 Ceiling System. Attaches to Knauf CD Channels with LN 3,5 screws. Can be cut and bend according to the suspension height
Field of Application
Designed exclusively to be used with Knauf D11 Ceiling System and W623 Wall Lining System.
download data sheet
Description
Galvanized accessories to connect Knauf CD Channels at intersection points in the Knauf D113 System grid. Delivered unbent. 2 Universal Connectors per intersection point.
Field of Application
Nonius Ceiling System (D112)
download data sheet
Description
Knauf Water Resistant Gypsum Backing Boards are ASTM C1396 compliant gypsum boards, specifically
designed for use in areas with humidity and exposure to moisture.
Field of Application
Knauf Water Resistant Gypsum Boards (GB-WR) are high performance gypsum boards used as the cladding component of drywall constructions in humid areas such as:
Description
These L-shaped suspensions have galvanized steel pre-painted polyester coating with the same color finishing as the tiles.
Field of Application
Suspension Grids for Lay in Type
Description
These consist of galvanized steel with pre-painted polyester coating aluminium or PPGI capping.
Field of Application
Suspension Grids for Lay in Type